Productbeschrijving

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 250-500 V, 50/60 Hz and DC.

Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:1
Rated Operational Voltage: Main Circuit 690V
Rated Frequency (f):Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A
Rated Operational Current AC-1 (Ie):(690 V) 55 °C 175 A
(690 V) 40 °C 200 A
(690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie):(690 V) 55 °C 80 A
(415 V) 55 °C 140 A
(220 / 230 / 240 V) 55 °C 140 A
(440 V) 55 °C 140 A
(380 / 400 V) 55 °C 140 A
(500 V) 55 °C 130 A
Rated Operational Power AC-3 (Pe):(500 V) 90 kW
(690 V) 75 kW
(220 / 230 / 240 V) 37 kW
(380 / 400 V) 75 kW
(440 V) 90 kW
(415 V) 75 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
Short-Circuit Protective Devices:gG Type Fuses 315 A
Rated Short-time Withstand Current (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
Maximum Electrical Switching Frequency:AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
Rated Operational Current DC-1 (Ie):(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie):(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie):(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Insulation Voltage (Ui):acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
Mechanical Durability:5 million
Maximum Mechanical Switching Frequency:300 cycles per hour
Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):60 Hz 250…500 V
50 Hz 250…500 V
DC Operation 250…500 V
Coil Consumption:Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A
Holding at Max. Rated Control Circuit Voltage DC 4 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 204 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A
Operate Time:Between Coil Energization and NO Contact Closing 25…55 ms
Between Coil De-energization and NO Contact Opening 37…47 ms
Connecting Capacity-Main Circuit:Flexible 2x10…70 mm²
Rigid Cu-Cable 2x10…95 mm²
Connecting Capacity-Auxiliary Circuit:Solid 2x1…4 mm²
Flexible with Insulated Ferrule 1x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:Double Clamp
Environmental
Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
Maximum Operating Altitude Permissible:3000 m
RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
Maximum Operating Voltage UL/CSA:Main Circuit 600 V
General Use Rating UL/CSA:(600 V AC) 200 A
Horsepower Rating UL/CSA:(208 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 40 Hp
Certificates and Declarations (Document Number)
CB Certificate:SE-70480
CCC Certificate:CQC_2013010304604055
Declaration of Conformity - CE:2CMT004242
RINA Certificate:ELE060313XG/002
RoHS Information:1SFC101055D0202